Tank Fluid Troubleshooting
Jun 05, 2025
Leave a message
Exploration of common problems of printing machine tank liquid - The selection of appropriate tank liquid concentration is based on the conductivity value. When the conductivity is too high, the ink will not dry easily, and when it is too low, the plate will be easily stained or ink will accumulate. Therefore, you must try to find the appropriate conductivity value. After finding the concentration value, multiply the total tank volume by the percentage to get the first addition amount. In addition, when the conductivity value changes by more than ±50~100, it needs to be corrected before it can be used again. At the same time, you also need to pay attention to the temperature in the water tank, because the temperature will affect the conductivity measurement value.
Generally, the ideal printing water conditions are recommended as follows:
(1) The water quality must be soft water;
(2) The conductivity value is 700~1300 (the conductivity value of water must be deducted);
(3) The pH value is 4.0~5.5;
(4) The tank temperature is 5℃~15℃;
(5) The emulsification degree is less than 35%;
(6) The alcohol IPA ratio is 5%~15%;
(7) The tank liquid concentration ratio is 1.5%~2.5%.
The following are the results of the actual tests conducted by our center in the printing laboratory:
Water tank: Magic 150
Conductivity meter: Delta OHM Conductivity Meter Model: HD 8706
PH meter: HANNA PH Meter Model: HI 8521
Based on the above example, the total amount of water tank in the printing machine water tank of the center's printing laboratory is 80,000cc*2%=1,600cc of water tank liquid, the conductivity value is maintained at 1,000 (1,095-92.5) ±100, and the pH value is about 5.0. In addition, we found that the pH value does not change significantly after the concentration of the water tank liquid reaches 3%, so it is difficult to detect whether the amount is appropriate. In addition, some European water tank liquids have more buffers added to keep the water tank liquid at a stable acidity and reduce the corrosion of the plate surface. Therefore, problems will arise when using the pH value to measure the concentration of the water tank liquid.